mirror of
https://github.com/KevinMidboe/mktxp-no-cli.git
synced 2025-10-29 17:50:23 +00:00
Merge pull request #16 from mikalstill/add-sfp-temperature
Add monitoring of SFP temperatures.
This commit is contained in:
@@ -25,7 +25,7 @@ class MonitorCollector(BaseCollector):
|
||||
if not router_entry.config_entry.monitor:
|
||||
return
|
||||
|
||||
monitor_labels = ['status', 'rate', 'full_duplex', 'name']
|
||||
monitor_labels = ['status', 'rate', 'full_duplex', 'name', 'sfp_temperature']
|
||||
monitor_records = InterfaceMonitorMetricsDataSource.metric_records(router_entry, metric_labels = monitor_labels, include_comments = True)
|
||||
if monitor_records:
|
||||
# translate records to appropriate values
|
||||
@@ -47,6 +47,9 @@ class MonitorCollector(BaseCollector):
|
||||
monitor_rates_metrics = BaseCollector.gauge_collector('interface_full_duplex', 'Full duplex data transmission', full_duplex_records, 'full_duplex', ['name'])
|
||||
yield monitor_rates_metrics
|
||||
|
||||
sfp_temperature_metrics = BaseCollector.gauge_collector('interface_sfp_temperature', 'Current SFP temperature', monitor_records, 'sfp_temperature', ['name'])
|
||||
yield sfp_temperature_metrics
|
||||
|
||||
# Helpers
|
||||
@staticmethod
|
||||
def _translated_values(monitor_label, value):
|
||||
@@ -54,7 +57,8 @@ class MonitorCollector(BaseCollector):
|
||||
'status': lambda value: '1' if value=='link-ok' else '0',
|
||||
'rate': lambda value: MonitorCollector._rates(value),
|
||||
'full_duplex': lambda value: '1' if value=='true' else '0',
|
||||
'name': lambda value: value
|
||||
'name': lambda value: value,
|
||||
'sfp_temperature': lambda value: value
|
||||
}[monitor_label](value)
|
||||
|
||||
@staticmethod
|
||||
|
||||
Reference in New Issue
Block a user